M
alfunctioning
E
ngine
S
tatistical
S
urvey
M.E.S.S.
Home
Report
Latest
Search
Search Result
Manufacturer
Estes Industries
Designation
A10-3T
Type
single-use
Date code
I21 1121
Failure date
Sep 9, 2023
Location
Irwindale CA
Temperature
95 ℉
Ejection end blown out
Burning propellant ejected
Have more motors
Comments
Failure at T+ 0.25 seconds after ignition.
Photos
Status
pending